Membrane
Filtration Unit Operation
Process
 |
conditioning
of feed mix in batching tank (pH etc.) |
 |
high
pressure circulation through membrane modules |
 |
selective
diafiltration by variation and controlling of temperature
and pressure |
 |
CIP-equipment
for a quick |
 |
change-over
automatic 1,000 l container filling device |
Layout
 |
capacity
of batching tank |
 |
35
m³ |
 |
capacity
of finished product tanks |
 |
2 x 25 m³ |
 |
filtering
surface |
 |
120
m² |
 |
membrane
material |
 |
e.g.
PCI AFC30 * |
 |
material
of pipes and tanks |
 |
stainless
steel |
 |
working
pressure |
 |
up
to 35 bars |
 |
temperature |
 |
up
to 70 °C |
 |
cutoff
molecular weight |
 |
800
- 1,000 g/mol * |
| |
|
|
|
| *
change-over to other membranes possible |
|
 |